IIMPAWU ZEHOT
Plasma Gel Card Centrifuge 12/24 Blood Grouping Ukuchwetheza Id Serological
| lwezicelo: | ● Uvavanyo lohlobo lwegazi lwe-ABO ● Uvavanyo lwe-antigen yeqela le-Rh ●Ukuhlolwa okungaqhelekanga kwe-antibody ● Umdlalo onqamlezileyo | ● Ukufunyanwa kwe-HDN ● Ukuhlolwa kwe-antibody yePlatelet ●Ukudibanisa iPlatelet |
| Isantya esiphezulu | Ngama-3500rpm | |
| Ubuninzi.RCF | 1554 xg | |
| Ubukhulu | Iikhadi le-24 | |
| IiRotors ezihambelanayo | Rotors ikhadi Disk | |
| Bonisa | LCD | |
| Inani Model: | XK-12B | |
| yokuqinisekisa: | CE, ISO13485,ISO9001:2015 | |
| iwaranti | Iwaranti yonyaka omnye kumatshini wonke, iwaranti yeminyaka emi-1 yecompressor kunye newaranti yeminyaka emi-3 yemoto. Iinxalenye ezitshintshiweyo zasimahla kunye nokuhanjiswa ngaphakathi kwewaranti. | |
- inkcazelo
- yokuzonwabisa
- Izikhankanyi Technical
- Rotors kunye nezixhobo
- Ithuba elihle lokhuphiswano
Itekhnoloji yejeli yekholomu encinci isetyenziswe kakhulu kwi-serology yegazi, ukufumanisa i-serum yesiqhelo, ukuhlamba iiseli ezibomvu zegazi, iimvavanyo ze-microcolumn gel immunoassay, kunye nezinye izicelo ngenxa yokusebenza kwayo okusemgangathweni kunye novavanyo olubuthathaka. I-XK-12B yekhadi le-gel yekhadi le-desktop ye-low-speed centrifuge ene-rotor ye-12/24 yekhadi ihlangabezana neemfuno zokusebenza eziqhelekileyo zokulungiswa kwebhetshi. Inkqubo ifaka ulawulo lwe-microcomputer kunye neteknoloji yokufumanisa ukungalingani ngokuzenzekelayo, iqinisekisa ukusebenza okulula kunye neziphumo zokufumanisa ezichanekileyo. Esi sixhobo sibalulekile kwi-hematology yovavanyo kwizibhedlele nakwiibhanki zegazi.
Umgaqo we-Blood Gel Card(ID-Card) Centrifuge
Umgaqo-siseko emva kwe-Blood Gel Card Centrifuge isekelwe kwi-microcolumn gel immunoreaction, ngokukodwa uvavanyo lwegazi olubomvu lwe-agglutination, eyaziwa ngokuba yi-microcolumn gel hemagglutination assay (MGHA). Ngaphakathi kwityhubhu yejeli ye-microcolumn, iiseli zegazi ezibomvu kunye nezilwa-buhlungu ezihambelana nazo ziyadibana zenze imbumba yeeseli ezibomvu zegazi. Ngokusebenzisa i-centrifugation enesantya esisezantsi, ihlwili libekwe phezu komhlaba okanye ngaphakathi kwejeli, ngelixa iiseli zegazi ezibomvu ezingabotshwanga kwi-antibody zihlala ezantsi kombhobho (incam yombhobho ongezantsi).
eziluncedo
Iingenelo ze-Micro Column Gel Technology zibandakanya ukulula kwayo ukusebenza, ukungabikho kokuhlamba kunye neemvavanyo zokuqinisekisa iziphumo ezibi, ezisombulula ingxaki yovavanyo lwe-Coombs olunzima ukuba lusetyenziswe ngokuqhelekileyo ekusebenzeni kweklinikhi ngenxa yobunzima bayo kunye nokuchitha ixesha. Ikwakhuthaza ithiyori yokufumanisa i-antibody engaphelelanga ukuba ibe “ngumgangatho wegolide” wekliniki. Inkqubo inokuqhuba iisampuli ezininzi ngexesha elinye (amakhadi e-12/24), evumela ukufunyanwa kwenani elikhulu leesampuli zeklinikhi. Ukongeza, ibonelela ngezinto eziluncedo ezinjengokuchaneka, ubuntununtunu, ukusetyenziswa kwesampulu encinci, ukugcinwa kwexesha elide leziphumo, ukubekwa emgangathweni ngokulula, kunye nokusebenza okukhuselekileyo.
Indlela yoVavanyo lobutata
Indlela yoVavanyo lwePaternity ibandakanya ukusetyenziswa kohlobo lwegazi lwe-ABO olulungileyo kunye nohlobo olubi kunye namakhadi ovavanyo lwegazi le-RhD ukuze kubonwe ii-antigens ze-ABO kunye ne-RhD. Indlela ye-column agglutination (indlela ye-microcolumn gel) yindlela esetyenziswa ngokuqhelekileyo ye-immunological yokuchongwa kweqela legazi, apho ii-antigens zegazi elibomvu kunye ne-antibodies ehambelanayo i-agglutinate kwi-microcolumn gel medium. Le ndlela isemgangathweni kwaye ilinganiswe, iqinisekisa ukuchaneka kweziphumo.
La manyathelo alandelayo ayabandakanyeka kwinkqubo:
I-1.Ingqokelela yeesampulu zegazi (qaphela: iisampulu eziqulethe iprotein ye-serum eyandisiweyo ngokungaqhelekanga kufuneka ihlanjwe ngokwaneleyo ngaphambi kokusetyenziswa).
2. Ukwenziwa kwesampulu yegazi:
(i) I-Centrifuge i-anticoagulated isampulu yegazi elipheleleyo kwi-900 ~ 1000g centrifugal force imizuzu emi-5, umaleko ongezantsi ziiseli ezibomvu zegazi ezigxininisiweyo ezinoxinzelelo olumalunga nama-80%. Ukufunxa ngononophelo i-plasma ephezulu kwenye ityhubhu yokuvavanya, enokusetyenziswa ngokuthe ngqo kuvavanyo.
(ii) Nciphisa iiseli ezibomvu zegazi ezipakishiweyo eziza kuvavanywa: Thatha i-8-10μl epakishwe iiseli ezibomvu zegazi kwaye wongeze i-1ml yeseli ebomvu yegazi. Ukubonakala kufuneka kube nokukhanya okufanayo okubomvu ngaphandle kweeflocs okanye i-blood clots. (iii) Nciphisa iiseli ezibomvu zegazi: Thatha i-8-10μl epakishwe iiseli ezibomvu zegazi kwaye wongeze i-1ml ye-diluent yeseli ebomvu yegazi. Ukubonakala kufuneka kube nokukhanya okufanayo okubomvu ngaphandle kweeflocs okanye i-blood clots.
3. Ukwenziwa kwekhadi lohlobo lwegazi:
1) Phawula ikhadi elilungisiweyo lejeli eliphilayo elilungisiweyo.
2) Yongeza ukunqunyanyiswa kweeseli ezibomvu zegazi kwityhubhu yokuqala ukuya kweyesine ngokulandelanayo, kwaye wongeze iiseli ezibomvu zegazi ezihlanjululweyo kwityhubhu yesihlanu ukuya kweyesithandathu.
3) Ngoko nangoko i-centrifuge imizuzu emi-5 (900rpm imizuzu emi-2, 1500rpm imizuzu emi-3) kwikhadi lodidi lwegazi centrifuge, kwaye uthathe isiphumo isigwebo iliso.
uyilo
● Ulawulo lweMicroprocessor ngeBrushless Motor. Ulawulo oluchanekileyo lwesantya.
● Ukusebenza ngokulula. Isikrini esinemibala yedijithali sibonisa zonke iiparamitha ezisebenzayo. Isivalo esizenzekelayo -vula i-alamu xa isixhobo sicinyiwe.
● Uyilo lwenkqubo yobungcali. Akukho mfuneko yokuseta ngesandla. Yibalekise nje.

Isebenziseka kakuhle
● Ukuvala isivalo ngokuzenzekelayo kunye nokubamba ngexesha lokuqhuba i-rotor.
● Isistim sokuzixilonga kunye ne-high-strength chamber-coating kunye nokukhusela.
● "Thulisa" iteknoloji enelungelo elilodwa lomenzi, isantya esiphezulu sokusebenza singaphantsi kwe-50 decibels.
● Uguqulelo lwe-rpm/rcf oluzenzekelayo.

Safety
● Iveliswe ngokwemigaqo yokhuseleko yamazwe ngamazwe (umz. IEC 61010).
● Ukhuseleko Isivalo sesivalo sombane, ucango alunakuvuleka xa i-rotor isebenza kwaye umatshini awuyi kusebenza xa isiciko sivuliwe kunye nekhowudi yempazamo ivela.
● Ukukhutshwa kwesiciko sesivalo sikaxakeka xa umbane usike (iluncedo kakhulu kuphazamiso lombane olungalindelekanga).
● Ukhuseleko lokhuseleko lwenzelwe isantya esingaphezulu ukuqinisekisa ukhuseleko kumatshini wendoda.

| Uluhlu lwesantya (rpm) | 0-3500rpm ehlengahlengiswayo | Ingxolo (dBA) | ≦50 dB(A) |
| Ubukhulu besakhono(ml) | Amakhadi angama-24 | Isilinganiselo (mm) | 430*320*250mm(amakhadi ali-12) 440*400*230mm(amakhadi ali-24) |
| Uluhlu lweRCF (xg) | 0-1554xg ehlengahlengiswayo | Ukusinda okushiyekile | 13 KG (namakhadi ali-12) 22KG (namakhadi angama-24) |
| Power unikezelo | AC220V,50HZ,5A,60W | ||
| Hayi. | umcimbi | isikhundla | Isantya sokujikeleza | Ubuninzi.RCF | ixesha | Phawula |
NO.1
| Iqela leprogram ye-Pre-centrifuge | Iikhadi le-12 | 3500r / min | 1232xg | 1 umzuzu | Iqela leprogram linokusetwa kumakhadi odidi lwegazi olwahlukileyo. |
NO.2
| Iqela lenkqubo yovavanyo | Iikhadi le-12 | 900r / min | 81xg | Imizuzu engama-2 | |
| 1500r / min | 226xg | Imizuzu engama-3 | ||||
NO.1
| Iqela leprogram ye-Pre-centrifuge | Iikhadi le-24 | 3500r / min | 1554xg | 1 umzuzu | |
NO.2
| Iqela lenkqubo yovavanyo | Iikhadi le-24 | 800r / min | 81xg | Imizuzu engama-2 | |
| 1335r / min | 226xg | Imizuzu engama-3 | ||||
![]() | ||||||
I-1.Umvelisi we-centrifuge oyingcali, ixabiso elikhuphisanayo.
I-2.ISO9001, i-ISO13485, i-CE, iSatifikethi se-SFDA, bonke oomatshini bafumana uvavanyo oluqinileyo lomgangatho kunye nokupakishwa okulungileyo ngaphambi kokuthutha.
I-3.Inkxaso yobugcisa bexesha elide kunye nenkonzo yabathengi abaqeqeshiweyo kwinqanaba ngalinye lokuthengiswa kwemveliso, ukuhanjiswa kunye nokusebenza.Iqela lethu lenkonzo eliqeqeshwe kakhulu kunye namava abonelela ngenqanaba elilodwa lenkxaso yokuthenga kwakho ubomi bonke.
I-4.Singakwazi kwakhona ukunika izisombululo ezilungiselelwe iimfuno ezikhethekileyo zabaxhasi.
I-5.Inamandla kunye neqela elisebenzayo leenjineli ezixhaswa yiminyaka yamava kwiinkalo zabo, inkampani iqinisekisa ukuba imveliso nganye eshiya iyunithi yokuvelisa ifikelele kumanqaku kuzo zonke iinkalo.